  1. Isothermal C.S.T.R

    Reactor : Material Stainless Steel, Capacity 2 Ltrs. (Approx).Water Bath : Material Stainless Steel, Double wall, insulated with Ceramic Wool Heater : Nichrome wire Heater Stirrer (2Nos.): Stainless Steel Impeller and shaft coupled with FHP motor. (One each for Water Bath and Reactor).Feed Tank (2Nos.): Material Stainless Steel, Capacity - 20 Ltrs.Feed Circulation: By compressed air.Flow Measurement: Rotameter 2 Nos. one each for Reactants.Piping : Stainless Steel and PVC.Pressure Regulator : 0-2 Kg/cm2 Pressure Gauge : Bourdon type 0-2 Kg/cm2 Stop Watch : Electronic Temp. Sensor : RTD PT-100 type Control panel comprises of : Digital Temp. Controller : 0-199.9°C (For Hot Water Bath) With Standard make on/off switch, Mains Indicator etc.Instruction Manual : An ENGLISH instruction manual will be provided along with the Apparatus SERVICES REQUIRED Compressed Air Supply at 2 Bar, 0.5 CFM.Electricity Supply : 1 Phase, 220 V AC, 1.5 kW.Instruments, Laboratory Glassware and Chemicals required for analysis as per the system adopted.
    Send Inquiry
  2. Cascade C.S.T.R

    Reactor (3Nos.) : Material Stainless Steel, Capacity 1 Ltr.(Approx)Stirrer (3Nos.) : Stainless Steel Impeller and shaft coupled with FHP Motor.Feed Tank (2Nos.): Material Stainless Steel, Capacity - 20 Ltrs.Feed Circulation: By compressed air.Flow Measurement: Rotameter 2 Nos. (one each for Reactants).Piping : Stainless Steel and PVC Pressure Regulator : 0-2 Kg/cm2 Pressure Gauge : Bourdon type 0-2 Kg/cm2 SERVICES REQUIRED Compressed Air Supply at 2 Bar, 0.5 CFM.Water Supply.Drain.Electricity Supply: 1 Phase, 220 V AC, 0.5 kW.
    Send Inquiry
  3. Plug Flow Reactor(Straight Tube Type)

    Reactor : Material Borosilicate Glass, OD-32mm, ID-25mm, Length-1200mm Feed Tank (2Nos.): Material Stainless Steel, Capacity - 20 Ltrs.Feed Circulation: By compressed air.Flow Measurement: Rotameter 2 Nos. (one each for Reactants).Piping : Stainless Steel and PVC Pressure Regulator: 0-2 Kg/cm2.Pressure Gauge: Bourdon type 0-2 Kg/cm2.Stop Watch: Electronic.Instruction Manual : An ENGLISH instruction manual will be provided along with the Apparatus The whole unit is assembled rigidly on a base plate and mounted on a stand.Most of the parts are powder coated and rest are painted with auto paints.SERVICES REQUIRED Compressed Air Supply at 2 Bar, 0.5 CFM.Water Supply.Drain.Instruments, Laboratory Glassware and Chemicals required for analysis as per the system adopted.
    Send Inquiry
  4. Plug Flow Reactor(Coiled Tube Type)

    Reactor : Material Stainless Steel, OD-16mm, ID-13mm approx.Feed Tank (2Nos.): Material Stainless Steel, Capacity - 20 Ltrs.Feed Circulation: By compressed air.Flow Measurement: Rotameter 2 Nos. (one each for Reactants).Piping : Stainless Steel and PVC Pressure Regulator: 0-2 Kg/cm2.Pressure Gauge: Bourdon type 0-2 Kg/cm2.Stop Watch: Electronic.Instruction Manual : An ENGLISH instruction manual will be provided along with the Apparatus The whole unit is assembled rigidly on a base plate and mounted on a stand.Most of the parts are powder coated and rest are painted with auto paints.SERVICES REQUIRED Compressed Air Supply at 2 Bar, 0.5 CFM.Water Supply.Drain.
    Send Inquiry
  5. Isothermal Plug Flow Reactor

    In an ideal Plug Flow Reactor (PFTR) there is no mixing in the direction of flow and complete mixing perpendicular to direction of flow. Concentration of reactants varies along the length of reactor but not in radial direction. In case of a coil turbulence is introduced due to frequent change in direction of flow and presence of secondary flow, so a higher value of reaction rate constant is expected in coil tube type plug flow reactor. This set-up is used to study a non-catalytic homogeneous reaction under isothermal condition. The set up consists of two feed tanks through which two reactants are fed to the reactor. Rotameters are provided to measure the individual flow of Chemicals. The flow rate can be adjusted by operating the needle valves provided on respective Rotameter. The compressed air is used for circulation of feed. It is a helical coil tube type reactor kept in a constant temperature water bath to conduct the experiment at various temperatures. Reactants enter at lower end coming out of the top of coil from where samples are collected for analysis.
    Send Inquiry
  6. Characteristics Of P.I.D Controller

    Stirred tank : Material stainless steel, capacity 2 Ltrs(approx.)stirrer : stainless steel ipeller and shaft coupled with FHP motor.Flow measureent : Rotameter Stop Watch : Electronic Heater : Nichrome wire heater Control Panel comprises of:- PID controller : 0-200 degree Celsius.Temperature Sensor:RTD PT-100 Type with standard make on/off switch, Mains indicator etc.An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the apparatus.The whole set-up is well designed and arranged on a rigid structure painted with industrial PU paint.SERVICES REQUIRED Water supply at 100 LPH(max)Floor drain Electricity supply: 1 phase, 220 V AC, 0.5 kw.Table for setup support.
    Send Inquiry
  7. Time Constant Of Manometer

    Manometer : Material Borosilicate Glass, U tube type, Height 1 m.pressure regulator : 0-2 kg/cm2 Stop Watch : Electronic An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the apparatus.The whole set-up is well designed and arranged on a rigid structure painted with industrial PU paint.SERVICES REQUIRED Constant compressed air supply at 1 CFM and pressure 2 to 3 kg/cm2.Table for set-up support.Manometer Fluid.
    Send Inquiry